OVA2 | Pentair Ortega Valve Adapter kit to CVA-24T Actuator

$79.99
In stock
SKU
OVA2
- +
Ask a Question

Ask a Question

OVA2 | Pentair Ortega Valve Adapter kit to CVA-24T Actuator

SKU#: OVA2

OVA2 Pentair Compool CVA-L24 Actuator to Ortega Valve, 2" Adapter 

$79.99

INSTALLATION:

  1. Remove the handle, cover, stop screw, and o-ring seals from Ortega Valve. Save cover screws.
  2. Insert new O-ring Seals into the bottom of the Adapter Plate. Lubricate Seals with Silicone Grease. In retrofit applications, it is advisable to remove the valve diverter and lubricate the diverter seal at this time. *
  3. Mount the Adapter plate to the valve, using the existing cover screws.
  4. Attach the Shaft Coupling to the valve shaft. ensure that pointer is oriented in the direction of the "open" valve port. Secure Coupling with Mounting Screws. Tighten the Screws completely.
  5. Secure the Actuator to the Adapter plate with Valve Actuator Mounting Screws.
  6. Attach Valve Handle to Valve Actuator, and secure it with Valve Knob.
  7. Connect cable between Valve Actuator and Power Center.
    Line up and attach Valve Actuator to the Shaft Coupling in this position, and reverse the cable plug on the side of the Valve Actuator so that the Actuator rotates to the correct position.

* Valves should be inspected and serviced at least once a year. The valve diverter should be well lubricated, the O-ring seals should be intact, and the diverter should fit snugly and rotate smoothly.

Ask a Question
OVA2 | Pentair Ortega Valve Adapter kit to CVA-24T Actuator OVA2 | Pentair Ortega Valve Adapter kit to CVA-24T Actuator
OVA2 | Pentair Ortega Valve Adapter kit to CVA-24T Actuator
  • Product Details

    About this product

    Description

    Highlights

    Kit Include

    • Includes: Adapter Plate, Cover O-Ring Seal, Shaft Coupling, Shaft Coupling Mounting Screws, Valve Handle, Valve Knob
    • OEM Pentair Parts

    Features

    INSTALLATION:

    1. Remove the handle, cover, stop screw, and o-ring seals from Ortega Valve. Save cover screws.
    2. Insert new O-ring Seals into the bottom of the Adapter Plate. Lubricate Seals with Silicone Grease. In retrofit applications, it is advisable to remove the valve diverter and lubricate the diverter seal at this time. *
    3. Mount the Adapter plate to the valve, using the existing cover screws.
    4. Attach the Shaft Coupling to the valve shaft. ensure that pointer is oriented in the direction of the "open" valve port. Secure Coupling with Mounting Screws. Tighten the Screws completely.
    5. Secure the Actuator to the Adapter plate with Valve Actuator Mounting Screws.
    6. Attach Valve Handle to Valve Actuator, and secure it with Valve Knob.
    7. Connect cable between Valve Actuator and Power Center.
      Line up and attach Valve Actuator to the Shaft Coupling in this position, and reverse the cable plug on the side of the Valve Actuator so that the Actuator rotates to the correct position.

    * Valves should be inspected and serviced at least once a year. The valve diverter should be well lubricated, the O-ring seals should be intact, and the diverter should fit snugly and rotate smoothly.