    About this product

    Description

    The Flowcell is designed to be used with a controller as part of a chemical automation system, which continuously monitors and maintains pH balance and sanitizer level in a swimming pool or spa.

    Highlights

    • Made from high-impact acrylic with Flow Switch
    • For Digital Controller Systems
    • Flow Switch Chemical Automation System Continuously Monitors and Maintains pH Balance and Sanitizer Level in a Swimming Pool and Spa.

    Features

    For Used Models

    555007…Control Two Sanitizer Sources with Digital pH/Dual ORP/FAC (ppm) Controller
    554500...pH Liquid Acid/ORP Liquid Chlorine System
    554510...pH/ORP Erosion Feeder System
    554511...pH/ORP Salt Generator System

    Operating Manual

    Brand Information

    Rola-Chem Corporation manufactures Peristaltic Pumps, pH/ORP Controllers, Chemical Storage Tanks and Flow Meters for the commercial swimming pool and SPA markets. Paradise Industries markets the Paradise SPA Vac™, Pool Sentry™ water leveler, Turbo Brush, Scumbug™ oil absorbing sponge Ultra Screen skimmer basket liner, Ultra Net skimmer net cover, Ultra Mitt cleaning glove, Ultra Patch pool cover patch, Ultra Strip solar cover patch, Ultra Handle hose carry / hanger and the Algae-Bugger II cartridge filter brush for the swimming pool and SPA Markets.

    Visit Manufacturers Website
  • Specifications

    6. Troubleshooting
    6.1 If Controller doesn’t appear to be reading correctly:
    6.1.1 Inspect Probes. See Cleaning in Maintenance section.
    6.1.2 Check the pH Probe with 7.2 pH buffer solution.
    The ORP Probe can be checked with a solution of 1 drop 5.25% bleach (i.e. household bleach) and 1 pint water. This should provide a 1-2 ppm free chlorine solution (check with test kit) Add one drop of chlorine at a time to adjust test mixture as required. Put ORP Probe in mixture. The ORP reading should be 600 to 800 mV.
    Note: It may take three to five minutes for Probes to respond to solution. If it takes longer you should replace the Probes.
    6.1.3 Adjust flowrate through Flowcell. Incorrect ORP/pH reading can occur if water is flowing too fast in the Flowcell. Variable speed circulation pumps can cause Float to indicate incorrectly. See Adjusting flow in Use of Flowcell section.
    6.1.4 Verify that Probe ends are in the flow stream of the Flowcell.
    6.2 If Controller flow light is not on:
    6.2.1 Confirm that adequate flow is going through the Flowcell.
    Open center Sampling Valve on the Flowcell. If light turns on, this may indicate a blockage between right (outlet) Flowcell fitting and the installation point on downstream side of the pool filter.
    6.2.2 Confirm that Flow Switch float is free to move.
    6.2.4 A filter on the inlet to the Flowcell can reduce contamination that can cause Flow Switch float to stick.
    NOTE: It is recommended that an inline filter be used to help keep the Globe Flowcell (including probes) and flow switch free from debris. Debris may cause obstruction in flow switch and prevent the switch from functioning