014124F | Raypak Gas Heater Direct Spark Ignitor
014124F | Raypak Gas Heater Direct Spark Ignitor
SKU#: 014124F
014124F Raypak Low NOx Pool And Spa Gas Heater - Model 259A, 409A Direct Spark Ignitor
IGNITER REMOVAL
1. Locate and remove front door panel.
2. Locate and remove the accessible left side access panel. You may also reach from the front of the heater or remove the jacket top for better access.
3. Locate the igniter behind the blower.
4. Locate and disconnect the high tension spark cable from the igniter.
5. Using a 5/16” socket, remove the (2) bolts holding the igniter down.
6. Using a flat screw driver, loosen the igniter bracket from the combustion chamber, preferably on both sides.
7. Carefully remove the igniter from its location. The ceramic is fragile, so handle with care.
8. When replacing or inspecting the igniter, the gap between the ground & spark tips should be 0.18”± 0.03”. The gap between the rods should be no less than 0.26” along their entire length.
-
Product Details
About this product
Description
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION Hard lighting at startup Igniter faulty Replace igniter Heater turns on for less than 4 seconds (no display error) Wiring
Incorrect supply wiring
PC Board short
Ignition not sensedCheck for loose or broken (verify continuity) wiring/ground/ignition wire.
Check incoming power for correct voltage. There should be no power on the neutral line.
Replace board if no strength signal is being detected.
Clean igniter with wire brush.Features
IGNITER REMOVAL
1. Locate and remove front door panel.
2. Locate and remove the accessible left side access panel. You may also reach from the front of the heater or remove the jacket top for better access.
3. Locate the igniter behind the blower.
4. Locate and disconnect the high tension spark cable from the igniter.
5. Using a 5/16” socket, remove the (2) bolts holding the igniter down.
6. Using a flat screw driver, loosen the igniter bracket from the combustion chamber, preferably on both sides.
7. Carefully remove the igniter from its location. The ceramic is fragile, so handle with care.
8. When replacing or inspecting the igniter, the gap between the ground & spark tips should be 0.18”± 0.03”. The gap between the rods should be no less than 0.26” along their entire length.Brand Information
For over 70 years, Raypak Raypak is a wholly owned subsidiary of Rheem Manufacturing and has been the world’s leading manufacturer of copper finned boilers and heaters. In 2000 Raypak’s primary manufacturing facility was relocated to a completely new 235,000 square foot building in Oxnard, California, its current headquarters. Raypak’s design goals are and have always been high quality, reliability and energy efficiency.
Visit Manufacturers Website -
Q/A
No Questions
Log in
Create a Free Account
Please fill out sign-up form
Sign up with your social media account
Or
Fill out sign up form
Why create an account
Sign up with your social media account