IGNITER REMOVAL
1. Locate and remove front door panel.
2. Locate and remove the accessible left side access panel. You may also reach from the front of the heater or remove the jacket top for better access.
3. Locate the igniter behind the blower.
4. Locate and disconnect the high tension spark cable from the igniter.
5. Using a 5/16” socket, remove the (2) bolts holding the igniter down.
6. Using a flat screw driver, loosen the igniter bracket from the combustion chamber, preferably on both sides.
7. Carefully remove the igniter from its location. The ceramic is fragile, so handle with care.
8. When replacing or inspecting the igniter, the gap between the ground & spark tips should be 0.18”± 0.03”. The gap between the rods should be no less than 0.26” along their entire length.

INSTALLATION & OPERATING INSTRUCTIONS

Ask a Question
014124F | Raypak Gas Heater Direct Spark Ignitor 014124F | Raypak Gas Heater Direct Spark Ignitor 014124F | Raypak Gas Heater Direct Spark Ignitor
014124F | Raypak Gas Heater Direct Spark Ignitor
  • Product Details

    About this product

    Description

    TROUBLESHOOTING

    PROBLEM CAUSE SOLUTION
    Hard lighting at startup Igniter faulty Replace igniter
    Heater turns on for less than 4 seconds (no display error) Wiring
    Incorrect supply wiring
    PC Board short
    Ignition not sensed

    Check for loose or broken (verify continuity) wiring/ground/ignition wire.
    Check incoming power for correct voltage. There should be no power on the neutral line.
    Replace board if no strength signal is being detected.
    Clean igniter with wire brush.

    Features

    IGNITER REMOVAL
    1. Locate and remove front door panel.
    2. Locate and remove the accessible left side access panel. You may also reach from the front of the heater or remove the jacket top for better access.
    3. Locate the igniter behind the blower.
    4. Locate and disconnect the high tension spark cable from the igniter.
    5. Using a 5/16” socket, remove the (2) bolts holding the igniter down.
    6. Using a flat screw driver, loosen the igniter bracket from the combustion chamber, preferably on both sides.
    7. Carefully remove the igniter from its location. The ceramic is fragile, so handle with care.
    8. When replacing or inspecting the igniter, the gap between the ground & spark tips should be 0.18”± 0.03”. The gap between the rods should be no less than 0.26” along their entire length.

    INSTALLATION & OPERATING INSTRUCTIONS

    Brand Information

    For over 70 years, Raypak Raypak is a wholly owned subsidiary of Rheem Manufacturing and has been the world’s leading manufacturer of copper finned boilers and heaters. In 2000 Raypak’s primary manufacturing facility was relocated to a completely new 235,000 square foot building in Oxnard, California, its current headquarters. Raypak’s design goals are and have always been high quality, reliability and energy efficiency.